Accessories
Fiber Optic Accessories: Splice Trays, Launch Boxes, Clamps and Sleeves
Fourteen items that never appear on a link budget yet decide whether an installation closes out. They group into four jobs: holding a splice, preparing the cable, testing the link, and hanging it from a pole. Minimum order runs from 1 pc to 2 km.
Splice trays and protection sleeves
Three trays cover the usual footprints: Tray A at 95.4 × 95.4 × 19.5 mm and Tray B at 167 × 126 × 26 mm, both ABS to UL 94 V-0, plus a 24-fiber tray at 105 × 225 mm, 100 g, 30 mm bend radius, splice holder included. Protection sleeves come in single and mass types — stainless steel reinforcement for one fiber, ceramic for 4, 6, 8 or 12-core ribbon — in 40 and 60 mm, shrinking at 110–130 °C with loss of 0.03 dB at −40 °C. Both seat inside the fiber optic splice closures, where capacity limits surface.
Preparing the cable
Furcation tube is the 3.0 or 2.0 mm PVC jacket with aramid yarn and a 1.1 mm inner tube that carries 250 µm coated or 900 µm buffered fiber into a 12-colour fan-out. Bare fiber reels are G.652D or G.657A on 125 µm cladding, at 33 and 15 mm minimum bend radius and 0.19–0.20 dB/km at 1550 nm. The single-mode cable spool is a different animal: duplex OS2 9/125 on OFNR riser jacket over 300 to 3,000 m, terminated SC, LC, FC or ST — a fiber optic patch cord on a reel rather than a cable for pulling.
Launch boxes and dummy fiber
An OTDR reads nothing useful in the first metres after its own port. The launch box puts 1,000 m of fiber in front of the pulse, waterproof and dustproof with an auto purge valve for altitude and temperature, −40 to +55 °C, under 1 dB at 1310 nm. Dummy bare fiber does the same on an open reel across 1 to 48 km. Both serve an instrument — the meters, sources and fault locators sit in the fiber optic test equipment range.
Aerial and drop hardware
The anchor clamp tensions 6–9 mm cable over spans to 90 m at 1.25 kN: nylon body and wedges, UV resistant, stainless bail with thimble. It is specified against the cable rather than the pole, so the limits belong with ADSS fiber optic cable. Inside, the riser split protection sleeve is 110 × 40 × 20 mm and taps six fibers, three each side.
The two items that are not passive
Two mini FTTH nodes close the list and are not spare parts: they convert 1310 or 1550 nm optical input to RF for a CATV or GPON drop, −15 to +2 dBm in, 65–82 dBuV out, WDM built in, SC/APC port.
All fourteen sit in the wider fiber optic components range. The 1650 nm fiber optic reflectors that mark a subscriber port for OTDR tracing have their own category, and the connector & patch cord guide covers the termination and cleaning steps that decide whether any of this hardware performs.