Gas/Water Block Microduct Connector | High-Pressure Sealing for Blown Fiber
The Gas/Water Block Microduct Connector is a critical safety component designed to provide a permanent, airtight, and watertight seal between a microduct and the fiber optic cable. Specifically engineered for transition points—such as entry into buildings, ODFs, or cabinets—this connector prevents hazardous gases, moisture, and debris from traveling through the duct system and damaging sensitive network equipment.
Key Features
-
Active Sealing Mechanism: Features a rotating ring or compression seal that can be tightened after the fiber cable has been blown through, ensuring a perfect fit around the cable jacket.
-
Crystal Clear Body: The transparent housing allows technicians to visually verify the cable position and ensure the seal is correctly seated.
-
Tool-Free Installation: Simple push-fit technology for the duct entry, with a manual locking nut to activate the gas/water barrier.
-
Safety First: Effectively blocks the migration of water and flammable gases into customer premises (CPE) or central offices.
Applications
-
Sealing transition points between outdoor microducts and indoor distribution frames.
-
Protecting underground manholes from water ingress into the wider duct network.
-
Ideal for FTTH, MDU, and SDU deployments where environmental integrity is required.
For standard splicing or duct-to-duct connections, explore our complete range of Micro Duct Connectors, including straight, reducer, and end-stop variants.
Frequently Asked Questions
Q: Why is a Gas/Water block connector necessary instead of a standard coupler?
A: Standard couplers join two ducts but do not seal the space around the cable. The Gas/Water block connector creates a physical barrier around the cable itself to stop fluid or gas migration.
Q: Can this connector be reused?
A: Yes. The high-quality HDPE and PC construction allows the connector to be opened and re-sealed multiple times for network maintenance or cable upgrades.
Q: At what pressure should the seal be activated?
A: You should only activate the gas seal after the fiber blowing process is complete. The connector is tested to maintain its seal even under 16 bar of internal pressure.
Specification
Material
| Components Material | ||
| 1 | Collet | POM |
| 2 | Locking Clip | POM |
| 3 | Cartridge | POM |
| 4 | Lock Claws | POM SUS301/304 |
| 5 | Support Ring | POM |
| 6 | O-Ring | TPE |
| 7 | Connector | POM |
| 8 | Lock nut | POM |
| 9 | Body | PC2807 |
| 10 | Silicone pad | Silicon rubber |
Technical Parameter
| Working with fluids | Air | Short term blowing pressure | 25Bar |
| Tightness | 0.15~0.8Mpa no Leak | Burst pressure | >40Bar |
| Tensile test | ≥65N to ≥2000N | Degree of protection | IP68 |
| Working Pressure | 15Bar | Insertion Force | 50N Max (5Kg) |
]
Specifications
| Specification | Duct OD / ID Ø mm |
Duct OD / ID Ø mm |
Tapered Hole Ø mm |
| 5/3.5-0.5-2.1 | 5/3.5 | 5/3.5 | 0.5-2.1 |
| 5/3.5-0.9-3.5 | 5/3.5 | 5/3.5 | 0.9-3.5 |
| 7/5.5-0.9-3.5 | 7/5.5 | 7/5.5 | 0.9-3.5 |
| 7/5.5-1-4 | 7/5.5 | 7/5.5 | 1-4 |
| 7/5.5-2-5.5 | 7/5.5 | 7/5.5 | 2-5.5 |
| 8/6-0.9-3.5 | 8/6 | 8/6 | 0.9-3.5 |
| 8/6-1-4 | 8/6 | 8/6 | 1-4 |
| 8/6-2-5.5 | 8/6 | 8/6 | 2-5.5 |
| 10/8-3-6 | 10/8 | 10/8 | 3-6 |
| 10/8-5-8 | 10/8 | 10/8 | 5-8 |
| 12/10-3-6 | 12/10 | 12/10 | 3-6 |
| 12/10-5-8 | 12/10 | 12/10 | 5-8 |
| 12/10-7-10 | 12/10 | 12/10 | 7-10 |
| 14/12-3-6 | 14/12 | 14/12 | 3-6 |
| 14/12-5-8 | 14/12 | 14/12 | 5-8 |
| 14/12-7-10 | 14/12 | 14/12 | 7-10 |
| 14/12-9-12 | 14/12 | 14/12 | 9-12 |
| 16/12-3-6 | 16/12 | 16/12 | 3-6 |
| 16/12-5-8 | 16/12 | 16/12 | 5-8 |
| 16/12-7-10 | 16/12 | 16/12 | 7-10 |
| 18/15-7-10 | 18/15 | 18/15 | 7-10 |
| 18/15-9-12 | 18/15 | 18/15 | 9-12 |
| 20/16-3-6 | 20/16 | 20/16 | 3-6 |
| 20/16-5-8 | 20/16 | 20/16 | 5-8 |
| 20/16-7-10 | 20/16 | 20/16 | 7-10 |
| 20/16-12-16 | 20/16 | 20/16 | 12-16 |